The Honeywell BW™ Ultra has been designed specifically for the sampling and monitoring of dangerous gases in confined spaces, before and after entry, Honeywell BW™ Ultra offers enhanced 1-Series sensor technology, visibility on gas readings, comfort, and connectivity. This makes it more reliable and provides an intuitive user experience, helping to prevent a potential gas safety incident.
Stock Status - Special Order on the supplier
The Honeywell BW Ultra portable gas detector will fit the shape of your hand – with a comfortable weight and a slimmer profile than the other five gas detectors – to minimise fatigue and offer enhanced productivity.
The one-button operation you’ve come to expect from Honeywell gas detectors. An internal pump and no snag points mean if you need to wear the Honeywell BW™ Ultra in tight spaces the detector will move with you.
Honeywell BW™ Ultra fully complies with all safety regulations in place by detecting the five gases for added protection at work.
Suitable applications for this Honeywell 5 sensor gas detector include oil & gas, pulp & paper, water treatment, shipping industry, chemical plants, or other industries for confined space entries.
PORTABLE / EASY TO USE / RELIABLE
CO | H2S | O2 | LEL | VOC | CO2 | SO2 | NH3 | H2 | CL2 | NO2 | HCN | NO
Ultra Easy
Ultra Visibility
Ultra Rugged
Ultra Connected
Ultra Comfortable
Ultra Quick
BW Ultra Specifications
Size |
14.8 x 8.5 x 4.0cm
|
Weight |
411 gram with clip
|
Temperature |
-20 to +50°c
|
Humidity |
0% - 95% RH [non-condensing]
|
Ingress Protection | IP66/68 |
Alarms & Type |
visual, vibrating, audible [95dB], Low, High, STEL, TWA, OL [over limit]
|
Self Test | Activated detectors automatically perform one internal diagnostic test every 24 hours (sensors, battery & circuitry) |
Pump | Sampe from up to 22.9m |
Typical Battery Life* | 18 hours [typical]; (14 hours with PID or IR sensor) at -20°c |
Connected Worker |
BluetoothTM Low Energy (BLE) - ability to connect to Honeywell's Safety Communicator App
Honeywell's TouchConnectTM - Easy ability to enter Bump or Calibration mode or change Set-Points
|
Event Logging | 30 alarm events and 10 bump events |
Data Logging | 45 days based on 8 hour shifts every 15 seconds logging |
User Options |
Adjust STEL period (5-15 minutes in 1 minute intervals)
Calibration Span levels
Calibration intervals
Bump test interval
Select combustible gas measurement: 0-100% LEL (lower explosive limit) or Methane gas 0-5.0% v/v
LEL and PID correction factors
Calibration due date (1 to 365 days, or set to sero for off)
Individual sensor enable /disable
Latching alarms
Stealth mode
Languages: English, French, German, Portuguese, Spanish, Simplified Chinese and Russian
|
Certificates & Approvals |
Class 1, Div 1, Gr A, B, C, D
Atex: II 1G Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
CE: European Conformity
|
Warranty |
Instrument: 3 years
Sensors: 3 years (2 years NH3, 1 year PID and Cl2)
Battery: 2 years
|
Oxygen (O2) |
0 - 25% Vol
|
0.1% vol |
Combustible Gases (LEL) | 0 - 100% LEL | 1% LEL |
Combustible Gases (IR)* | 1 - 5.00% vol | 0.01% vol |
Hydrogen Sulfide (H2S) | 0 - 100 ppm | 1 ppm / 0.1 ppm |
Carbon Monoxide (C0) | 0 - 2,000 ppm | 1 ppm |
Carbon Monoxide (Low H2) (C0-H) | 0 - 1,000 ppm | 1 ppm |
Sulfur Dioxide (S02) | 0 - 100 ppm | 0.1 ppm |
Hydrogen (H2) | 0 - 2,000 ppm | 5 ppm |
Carbon Dioxide (C02) | 0 - 50,000 ppm | 100 ppm |
Ammonia (NH3) | 0 - 100 ppm | 1 ppm |
Volatile Organic Compounds (VOC)** | 0 - 1,000 ppm | 1 ppm |
Chlorine (CL2) | 0 - 20 ppm | 0.1 ppm |
Nitrogen Dioxide (N02) | 0 - 50 ppm | 0.1 ppm |
Hydrogen Cyanide (HCN) | 0 - 100 ppm | 0.1 ppm |
Nitrogen Monoxide (N0) | 0 - 200 ppm | 1 ppm |
Download the Honeywell BW Ultra data sheet.
BW Ultra Special Order
When you see 'Special Order' products available for purchase on our website it means they will be sourced on-demand from our suppliers when you place your order. Products typically have this status when the product is not actively stocked within our warehouse but are available to order.
This may be due to the shelf life or the specialty nature of some of our products (ie: gas detection and specialty gases) or the need to custom manufacture a product to fit/suit the application.
Once we have received your order and payment confirmation we will place an order with the Supplier.
Gas Detectors / Specialty gases (ie: short shelf-life products) - may take up to 4 weeks (please note this can vary per supplier availability and manufacturing schedules) to be receipted into our store. You will receive an estimated date of shipping once we have received confirmation from our Supplier.
Custom Manufacturing - for items that require custom manufacturing you will receive an estimated date of shipping once we have received confirmation from our Supplier.
From time to time a supplier may not be able to supply in the time indicated, and items are placed on backorder. If it appears that your order will not be dispatched on time, you will be informed as soon as possible. You will be offered the opportunity to cancel your order at that time, otherwise, your order will be dispatched as soon as the items are available.
Valid to the 30th November 2024 or while stock lasts
Purchase Now
https://www.gasdetectorshop.com.au/multi-gas-detectors/honeywell-bw-flex-portable-gas-detector