http://schema.org/OutOfStock
Product Code: GDMULTIRAE-LITE
Availability: Special Order
Sensor Gas Type: O2, LEL, CO, H2S, CO2, SO2, VOC, PID
Gas Quantity: 6 Gases
O2 Sensor Life: 2-year
Typical Battery Life: Rechargeable Li-ion 12 hr [typical]; recharges in less than 6 hours
Warranty: 2-year warranty on non-consumable components, 1-year on all other sensors, pump, battery, and other consumable parts
Call for Price: 1800 234 477

Available Options

MultiRAE Lite Sensor & Wireless Options:
Lite-Diffusion / CO₂ / LEL / H2S / O₂ / Li-ion / No Wireless
Lite-Diffusion / CO₂ / LEL / H2S / O₂ / Li-ion / Wireless (868Hz)
Lite-Pumped / 10.6 eV PID / LEL / CO + H₂S / SO₂ / O₂ / Li-ion / No Wireless
Lite-Pumped / 10.6 eV PID / LEL / H₂S / CO / O₂ / Li-ion / No Wireless
Lite-Pumped / 10.6 eV PID / LEL / H₂S / CO / O₂ / Li-ion / Wireless (868Hz)
Lite-Pumped / CO₂ / LEL / CO / O₂ / Li-ion / No Wireless
Lite-Pumped / CO₂ / LEL / CO / O₂ / Li-ion / Wireless (868Hz)
Lite-Pumped / O₂ / LEL / H₂S / CO / SO₂ / Li-ion / No Wireless
Lite-Pumped / O₂ / LEL / H₂S / CO / SO₂ / Li-ion / Wireless (868Hz)

The MultiRAE Lite is a versatile, customisable portable multi-gas detector for monitoring up to six gases.

A pumped gas detector with a rechargeable battery (non-wireless option)

Multi-gas detector VOC | PID | LEL | H2S | CO | O2 | CO2 | SO2

Stock Status - Special Order on the supplier.

Please email us for pricing - This email address is being protected from spambots. You need JavaScript enabled to view it.

PORTABLE / EASY TO USE / RELIABLE

VOC | PID | LEL | H2S | CO | O2 | CO2 | SO2

The MultiRAE Lite gas detector offers more than 25 sensors to choose from, it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a variety of industries and applications.

This handheld PID gas detector offers data logging and an optional wireless connection that sends threat and alarm data in real-time to a central command, providing superior awareness for fast incident response. 

With replaceable sensors, alarms, and batteries, a large screen, and automated bump testing and calibration, the MultiRAE Lite is easy to use and maintain. 

This PID gas detector is suitable for Melbourne Water, pairing the MultiRAE Lite non-wireless, PID, LEL, NH3, O2, CO/H2S, pumped version with a rechargeable battery with the RAE Systems 6" flexible probe [GD023-3012-000]

The MultiRAE Lite features: 

  • Multi-gas monitor for 1-6 gases
  • Pumped and diffusion models are available
  • Man down alarm
  • More than 25 different chemical sensors
  • Fully automatic bump testing and calibration
  • Real-time access to readings at the central command
  • Swap out sensors as needed

MultiRAE Lite Specifications

Size 19.3 x 9.7 x 6.6 cm
Weight  880g 
Sensors  Over 25 intelligent interchangeable field-replaceable sensors including PID1 for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors and CO2 NDIR sensors
Battery Options, Runtime, Recharge Time 
  • Rechargeable Li-ion 12 hr (pumped) / 18 hr (diffusion) runtime, < 6 hr recharge time
  • Extended duration Li-ion  18 hr (pumped) / 28 hr (diffusion) runtime, < 9 hr recharge time
  • Alkaline adapter with 4 x AA batteries 6 hr (pumped) / 8 hr (diffusion) runtime
Display Monochrome graphical LCD display (128 x 160) with backlighting. Automatic screen "flip" feature
Display Readout
  • Real-time reading of gas concentrations; PID measurement gas and correction factor; Man Down Alarm on/off; visual compliance indicator; battery status; data logging on/off; wireless on/off and reception quality
  • STEL, TWA, peak and minimum values
Keyboard Buttons 3 operation programming keys (Mode, Y/+, and N/-)
Sampling Built-in pump or diffusion
Calibration Automatic with AutoRAE 2 Test and Calibration System3 or manual
Alarms
  • Wireless remote alarm notification; audible (95dB @ 30cm), vibration, visible (flashing bright red LEDs) and on-screen indication of alarm conditions
  • Man Down Alarm with pre-alarm and real-time remote wireless notification2
Data Logging Continuous data logging (6 months for 5 sensors at 1-minute intervals, 24/7) - user-configurable data logging intervals (from 1 to 3,600 seconds)
Communication & Data Download
  • Data download and instrument set-up and upgrades on PC via desktop charging and PC comm. cradle, travel charger or AutoRAE 2 Automatic Test and Calibration system3
  • Wireless data and alarm status transmission via built-in RF modem (optional)
Wireless Network ProRAE Guardian REal-Time Wireless Safety System or EchoView Host-based Closed-Loop System
Wireless Range (typical) MultiRAE Lite to RAELink3 [Z1] Mesh modem - 100 metres
MultiRAE Lite to EchoView Host, RAEMesh Reader or RAEPoint - 200 metres
MultiRAE Lite Wi-Fi to Access Point - 100 metres
Operating Temperature -20ºc to +50ºc
Humidity 0% to 95% relative humidity (non-condensing)
Dust & Water Resistance IP65 (pumped)  IP67 (diffusion) ingress protection rating
Safety Certifications CSA: Class I, Div. 1, Groups A, B, C, D, T4       Class II, Div. 1, Groups E, F, G T85ºc
ATEX: 0575 II 1G Ex ia IIC T4      2G Ex ia d IIC T4 Gb with IR Sensor installed      IM1 Ex ia I Ma
IECEx: Ex  ia IIC T4 Ga     EX ia d IIC T4 Gb with IR Sensor installed     IM1 Ex ia I Ma
IECEx/ANZEx:  Ex ia IIC T4 Ga      Ex ia d IIC T4  Gb  with IR Sensor installed     Ex ia I Ma
EMI/RFI8 EMC directive: 2004/108/EC
Performance Tags LEL CSA C22.2 No. 152, isa-12.13.01
Warranty
  • Two years on non-consumable components and catalytic LEL, CO H2S, and O2 sensors
  • One year on all other sensors, pump, battery, and other consumable parts
Wireless Frequency ISM license-free band. IEEE 802.15.4 Sub 1 GHz     Wi-Fi 802.11 b/g 
Wireless Approvals FCC Part 15, CE R&TTE, Others4
Radio Module Supports RM900A

MultiRAE Lite Sensor Specifications

PID Sensor4 

VOC 10.6 eV 
Range: 0 to 1,000 ppm
Resolution: 1ppm

Combustible Sensors 

Catalytic LEL
Range: 0 to 100% LEL
Resolution: 1% LEL
NDIR (0 - 100% LEL Methane)
Range: 0 to 100% LEL
Resolution: 1% LEL
NDIR (0 - 100% Vol. Methane)5
0 to 100% Vol.
Resolution: 0.1% Vol.

Carbon Dioxide 

Carbon Dioxide (CO2)
Range: 0 to 50,000 ppm
Resolution: 100 ppm

Electrochemical Sensors

Ammonia (NH3)
Range: 0 to 100 ppm 
Resolution: 1ppm
Carbon Monoxide (CO)
Range: 0 to 500 ppm
Resolution: 1 ppm
Carbon Monoxide (CO), Ext. Range
Range: 0 to 2,000 ppm
Resolution:  10 ppm
Carbon Monoxide (CO), H2-comp.
Range: 0 to 500 ppm
Resolution:  10 ppm
Carbon Monoxide (CO) + Hydrogen Sulfide (H2S) Combo
Range: 0 to 200 ppm
Resolution: 0.1 ppm  
Chlorine (CI2)
Range: 0 to 50 ppm
Resolution:  0.1 ppm
Chlorine Dioxide (CIO2)
Range: 0 to 1 ppm
Resolution:  0.03 ppm
Ethylene Oxide (EtO-A)
Range: 0 to 100 ppm
Resolution:  0.5 ppm
Ethylene Oxide (EtO-B)
Range: 0 to 10 ppm
Resolution:  0.1 ppm
Ethylene Oxide (EtO-C), Ext. Range9
Range: 0 to 500 ppm
Resolution:  10 ppm
Formaldehyde (HICHO)
Range: 0 to 10 ppm
Resolution:  10 ppm
Hydrogen (H2)9
Range: 0 to 1,000 ppm 
Resolution:  10 ppm
Hydrogen Cyanide (HCN)
Range: 0 to 50 ppm
Resolution: 0.5 ppm
Hydrogen Sulfide (H2S)
Range: 0 to 100 ppm
Resolution: 0.1 ppm
Hydrogen Sulfide (H2S), Ext. Range9
Range: 0 to 1,000 ppm
Resolution: 1 ppm
Methyl Mercaptan (CH3-SH)
Range: 0 to 10 ppm
Resolution: 0.1 ppm
Nitric Oxide (NO)
Range: 0 to 250 ppm
Resolution: 0.5 ppm
Nitrogen Dioxide (NO2)
Range: 0 t0 20 ppm
Resolution: 0.1 ppm
Oxygen (O2)
Range: 0 to 30% Vol.
Resolution: 0.1% Vol.
Phosphine (PH3)
Range: 0 to 20 ppm
Resolution: 0.1 ppm
Sulphur Dioxide (SO2)
Range: 0 to 20 ppm
Resolution: 0.1 ppm 
  1. A two-gas combination sensor is required for a 6-gas configuration.
  2. Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.
  3. AutoRAE 2 supports the MultiRAE Lite pumped version only.
  4. PID sensor requires a pumped configuration.
  5. NDIR combustible sensors require a pumped configuration in CSA countries.
  6. RAE Systems recommends calibrating sensors on installation.
  7. Specifications are subject to change.
  8. Specification for non-wireless monitors.
  9. Supported in MultiRAE Lite Diffusion only.
  10. Please contact RAE Systems for specific wireless approvals.

MultiRAE Lite Applications

  • Clandestine Labs
  • Confined Space Entry
  • Emergency Response
  • Environmental Cleanups/Remediation
  • Exploration
  • Fire Overhaul
  • Fracking
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Urban Search & Rescue

MultiRAE Lite Special Order

When you see 'Special Order' products available for purchase on our website it means they will be sourced on-demand from our suppliers when you place your order. Products typically have this status when they are not actively stocked within our warehouse but are available to order.

This may be due to the shelf life or the specialty nature of some of our products (ie: gas detection and specialty gases) or the need to custom manufacture a product to fit/suit the application.

Once we have received your order and payment confirmation we will place an order with the Supplier.

Gas Detectors / Specialty gases (ie: short shelf-life products) - may take up to 4 weeks (please note this can vary per supplier availability and manufacturing schedules) to be receipted into our store. You will receive an estimated date of shipping once we have received confirmation from our Supplier.

Custom Manufacturing - for items that require custom manufacturing you will receive an estimated date of shipping once we have received confirmation from our Supplier. 

From time to time a supplier may not be able to supply in the time indicated, and items are placed on backorder. If it appears that your order will not be dispatched on time, you will be informed as soon as possible. You will be offered the opportunity to cancel your order at that time, otherwise, your order will be dispatched as soon as the items are available.

There are no reviews for this product.
Write a review
Facebook comment