The MultiRAE Lite is a versatile, customisable portable multi-gas detector for monitoring up to six gases.
A pumped gas detector with a rechargeable battery (non-wireless option)
Multi-gas detector VOC | PID | LEL | H2S | CO | O2 | CO2 | SO2
Stock Status - Special Order on the supplier.
Please email us for pricing -
PORTABLE / EASY TO USE / RELIABLE
VOC | PID | LEL | H2S | CO | O2 | CO2 | SO2
The MultiRAE Lite gas detector offers more than 25 sensors to choose from, it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a variety of industries and applications.
This handheld PID gas detector offers data logging and an optional wireless connection that sends threat and alarm data in real-time to a central command, providing superior awareness for fast incident response.
With replaceable sensors, alarms, and batteries, a large screen, and automated bump testing and calibration, the MultiRAE Lite is easy to use and maintain.
This PID gas detector is suitable for Melbourne Water, pairing the MultiRAE Lite non-wireless, PID, LEL, NH3, O2, CO/H2S, pumped version with a rechargeable battery with the RAE Systems 6" flexible probe [GD023-3012-000]
The MultiRAE Lite features:
MultiRAE Lite Specifications
Size | 19.3 x 9.7 x 6.6 cm |
Weight | 880g |
Sensors | Over 25 intelligent interchangeable field-replaceable sensors including PID1 for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors and CO2 NDIR sensors |
Battery Options, Runtime, Recharge Time |
|
Display | Monochrome graphical LCD display (128 x 160) with backlighting. Automatic screen "flip" feature |
Display Readout |
|
Keyboard Buttons | 3 operation programming keys (Mode, Y/+, and N/-) |
Sampling | Built-in pump or diffusion |
Calibration | Automatic with AutoRAE 2 Test and Calibration System3 or manual |
Alarms |
|
Data Logging | Continuous data logging (6 months for 5 sensors at 1-minute intervals, 24/7) - user-configurable data logging intervals (from 1 to 3,600 seconds) |
Communication & Data Download |
|
Wireless Network | ProRAE Guardian REal-Time Wireless Safety System or EchoView Host-based Closed-Loop System |
Wireless Range (typical) | MultiRAE Lite to RAELink3 [Z1] Mesh modem - 100 metres |
MultiRAE Lite to EchoView Host, RAEMesh Reader or RAEPoint - 200 metres | |
MultiRAE Lite Wi-Fi to Access Point - 100 metres | |
Operating Temperature | -20ºc to +50ºc |
Humidity | 0% to 95% relative humidity (non-condensing) |
Dust & Water Resistance | IP65 (pumped) IP67 (diffusion) ingress protection rating |
Safety Certifications | CSA: Class I, Div. 1, Groups A, B, C, D, T4 Class II, Div. 1, Groups E, F, G T85ºc |
ATEX: 0575 II 1G Ex ia IIC T4 2G Ex ia d IIC T4 Gb with IR Sensor installed IM1 Ex ia I Ma | |
IECEx: Ex ia IIC T4 Ga EX ia d IIC T4 Gb with IR Sensor installed IM1 Ex ia I Ma | |
IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor installed Ex ia I Ma | |
EMI/RFI8 | EMC directive: 2004/108/EC |
Performance Tags | LEL CSA C22.2 No. 152, isa-12.13.01 |
Warranty |
|
Wireless Frequency | ISM license-free band. IEEE 802.15.4 Sub 1 GHz Wi-Fi 802.11 b/g |
Wireless Approvals | FCC Part 15, CE R&TTE, Others4 |
Radio Module | Supports RM900A |
MultiRAE Lite Sensor Specifications
PID Sensor4
VOC 10.6 eV |
Range: 0 to 1,000 ppm
Resolution: 1ppm
|
Combustible Sensors
Catalytic LEL |
Range: 0 to 100% LEL
Resolution: 1% LEL
|
NDIR (0 - 100% LEL Methane) |
Range: 0 to 100% LEL
Resolution: 1% LEL
|
NDIR (0 - 100% Vol. Methane)5 |
0 to 100% Vol.
Resolution: 0.1% Vol.
|
Carbon Dioxide
Carbon Dioxide (CO2)
|
Range: 0 to 50,000 ppm
Resolution: 100 ppm
|
Electrochemical Sensors
Ammonia (NH3)
|
Range: 0 to 100 ppm
Resolution: 1ppm
|
Carbon Monoxide (CO)
|
Range: 0 to 500 ppm
Resolution: 1 ppm
|
Carbon Monoxide (CO), Ext. Range
|
Range: 0 to 2,000 ppm
Resolution: 10 ppm
|
Carbon Monoxide (CO), H2-comp.
|
Range: 0 to 500 ppm
Resolution: 10 ppm
|
Carbon Monoxide (CO) + Hydrogen Sulfide (H2S) Combo
|
Range: 0 to 200 ppm
Resolution: 0.1 ppm
|
Chlorine (CI2)
|
Range: 0 to 50 ppm
Resolution: 0.1 ppm
|
Chlorine Dioxide (CIO2)
|
Range: 0 to 1 ppm
Resolution: 0.03 ppm
|
Ethylene Oxide (EtO-A)
|
Range: 0 to 100 ppm
Resolution: 0.5 ppm
|
Ethylene Oxide (EtO-B)
|
Range: 0 to 10 ppm
Resolution: 0.1 ppm
|
Ethylene Oxide (EtO-C), Ext. Range9
|
Range: 0 to 500 ppm
Resolution: 10 ppm
|
Formaldehyde (HICHO)
|
Range: 0 to 10 ppm
Resolution: 10 ppm
|
Hydrogen (H2)9
|
Range: 0 to 1,000 ppm
Resolution: 10 ppm
|
Hydrogen Cyanide (HCN)
|
Range: 0 to 50 ppm
Resolution: 0.5 ppm
|
Hydrogen Sulfide (H2S)
|
Range: 0 to 100 ppm
Resolution: 0.1 ppm
|
Hydrogen Sulfide (H2S), Ext. Range9
|
Range: 0 to 1,000 ppm
Resolution: 1 ppm
|
Methyl Mercaptan (CH3-SH)
|
Range: 0 to 10 ppm
Resolution: 0.1 ppm
|
Nitric Oxide (NO)
|
Range: 0 to 250 ppm
Resolution: 0.5 ppm
|
Nitrogen Dioxide (NO2)
|
Range: 0 t0 20 ppm
Resolution: 0.1 ppm
|
Oxygen (O2)
|
Range: 0 to 30% Vol.
Resolution: 0.1% Vol.
|
Phosphine (PH3)
|
Range: 0 to 20 ppm
Resolution: 0.1 ppm
|
Sulphur Dioxide (SO2)
|
Range: 0 to 20 ppm
Resolution: 0.1 ppm
|
MultiRAE Lite Applications
MultiRAE Lite Special Order
When you see 'Special Order' products available for purchase on our website it means they will be sourced on-demand from our suppliers when you place your order. Products typically have this status when they are not actively stocked within our warehouse but are available to order.
This may be due to the shelf life or the specialty nature of some of our products (ie: gas detection and specialty gases) or the need to custom manufacture a product to fit/suit the application.
Once we have received your order and payment confirmation we will place an order with the Supplier.
Gas Detectors / Specialty gases (ie: short shelf-life products) - may take up to 4 weeks (please note this can vary per supplier availability and manufacturing schedules) to be receipted into our store. You will receive an estimated date of shipping once we have received confirmation from our Supplier.
Custom Manufacturing - for items that require custom manufacturing you will receive an estimated date of shipping once we have received confirmation from our Supplier.
From time to time a supplier may not be able to supply in the time indicated, and items are placed on backorder. If it appears that your order will not be dispatched on time, you will be informed as soon as possible. You will be offered the opportunity to cancel your order at that time, otherwise, your order will be dispatched as soon as the items are available.